Nr | Parameter2) | Description | Comments |
1 | Radiocommunication service | Fixed | - |
2 | Application | Point-to-Point | CCDP (Co-Channel Dual Polarized) ACCP (Adjacent Channel Co-Polarization) |
3 | Frequency band | A: 10.700 - 11.200 GHz B: 11.200 - 11.700 GHz | - |
4 | Channelling | 28 MHz | Channelling: centre frequencies according to CEPT/ERC/REC 12-06, Annex A. |
5 | Modulation / Occupied bandwidth | Class: 5HB (128-QAM or equivalent). ACM is allowed. OBW: 28 MHz. | Definition of spectral efficiency classes: refer to EN 302 217-2, clause 4.1.1.3. Adaptive Modulation (ACM) is allowed. OBW with Class 5HB (128-QAM): 28 MHz with or without ACM. |
6 | Direction / Separation | 530 MHz | FDD |
7 | Transmit power / Power density | Max. 55 dBW e.i.r.p. | The operational e.i.r.p. will be specified in the license / individual assignment. |
8 | Channel access and occupation rules | - | - |
9 | Authorisation regime | Switzerland: License required. Liechtenstein: Individual assignment required. | Geographical restrictions: Exclusion areas in Canton Valais and in town areas of Bale and Zürich. |
10 | Additional essential requirements | - | - |
11 | Frequency planning assumptions | EN 302 217-2. Nominal RX input level = - 50 dBm. ATPC control range = min. 15 dB to max. 20 dB. | Conditions for the nominal RX input level: - Receiver input, point A in the system block diagram (EN 302 217-1), - RX input level tolerance: +1 to -10 dB, - ATPC set to min. TX output power in clear sky conditions (i.e. without rain fading). ===== ATPC power increases shall be triggered on the basis of propagation effects only. The ATPC system shall not remain at max. available power (EN 302 217-1, clause 3.1) for more than 15 consecutive minutes (ITU-R Rec. F.750). ===== Remote Transmit Power Control (RTPC) is considered to be an optional feature. ===== At first CCDP has to be used and then ACCP. ===== Limits for the occupied bandwidth: refer to EN 302 217-2, clause 4.2.3.2, unified spectrum masks, Figure 7. ===== Allowed Reference Mode for ACM: - 28 MHz channelling with 128-QAM modulation. ===== Min. link distance = 10 km. Site sharing radius = 900 m. ===== Class 3 antenna. Min. antenna gain = 40 dBi. Linear (horizontal or vertical) polarization. Antenna Radiation pattern envelope (RPE) according to EN 302 217-4, Figure 13. OFCOM may impose tighter requirements than the minimum values given in EN 302 217-4 in order to maximize the use of the scarce spectrum resources. |
12 | Planned changes | - | - |
13 | Reference | EN 302 217-2 /-/ CEPT/ERC/REC 12-06. | Effective use of spectrum / ECC Decisions / ECC Recommendations. |
14 | Notification number | G/TBT/N/CHE/238 2019/9504/CH | - |
15 | Remarks | EN 301 489-4 | - |
Normative part: 1 to 11
Informative part: Nr 12 to 15
1) RIR for similar and/or other applications are available under: https://www.bakom.admin.ch/bakom/en/home/frequenzen-antennen/nationaler-frequenzzuweisungsplan/schnittstellen-anforderungen.html
2) For explanations and legal status, please refer to basis document 784.101.21 / RIR0000
© OFCOM (Swiss Federal Office of Communications)